Modifying a source term in an XML/HTML translated field can lose translations
if the same term is translated in several languages.
closesodoo/odoo#29078
The other methods do test password length before verifying it, so even
if check_credentials() is not meant to be called directly, it's better
to keep it consistent with the alternatives.
Closes#29023
- This commit fixes a crash that happens when the server receive a
JSON-P call done in two requests (a POST followed by a GET).
The issue is due to the fact that when the first request is done (POST
one) the member `params` is never initialized.
This parameter is then used in the module `auth_signup` on an override
of the method `dispatch` thus crashing the code.
To avoid the crash, we now initialize `params`.
closesodoo/odoo#27369
The adaptation to Python 3 was done with two mistakes: the iteration on the lru
cache does not return keys, and functions are not sortable.
closesodoo/odoo#28870
Implement the getter method in plain SQL. This makes reading company-dependent
fields 33% faster (on 20000 partners, reading 'property_product_pricelist'
takes 3700ms instead of 5500ms.)
closesodoo/odoo#28769
PKG-INFO is generated during the setup phase and is not needed anymore.
Also this file contains outdated informations.
py2exe is not used anymore to build the windows installer.
closesodoo/odoo#28494
When changing the field `image` on `res.users`, the `write_date` of the user is
not updated because the field is inherited from `res.partner`.
Related to Issue : 1839603
Due to the implementation of PEP-475[1] in Python 3.5, revision
e98e8e9b1b used the recommended technique
of wakeup file descriptors in order to detect interruption of sleep() and
select() by signals, when running in multi-process mode (workers > 0).
The technique works well, however the initial patch never bothered to
read the byte that is written to the wakeup pipe when a signal is
processed. This does not matter when the signal is meant to shut down
the server, but it matters when the signal is SIGQUIT: it simply prints
thread dumps, and continues operating normally.
As a consequence, that byte remains in the wakeup pipe forever, causing
all the subsequent select/sleep calls to return immediately because
the wakeup fd *is* already ready. The symptom was that worker
processes would start cycling their main run loop very fast after
receiving a SIGQUIT signal, eating 100% CPU.
This patch ensures we always empty the wakeup pipe after an interruptible
call, to avoid this effect. It also refactors another occurrence of the
"empty pipe" pattern, in the PreforkServer, and incidentally uses readable
aliases for the file descriptors bound to the ends of the wakeup pipe
(wakeup_fd_r / wakeup_fd_w).
[1] https://www.python.org/dev/peps/pep-0475closesodoo/odoo#28356
Consider a many2one field `foo_id` on model `bar`, with an inverse one2many
field `bar_ids` on model `foo`. During an onchange, the statement
bar.foo_id = foo
puts a special value in cache to add `bar` to the value of `foo.bar_ids`
without explicitly reading `foo.bar_ids`.
Executing the above statement a second time, the cache of `foo.bar_ids` is no
longer empty. This causes the actual value of `foo.bar_ids` to be read and
updated. The issue is that this can be slow for large values of `foo.bar_ids`.
Avoid reading the value of the one2many field by handling the case where the
cache contains the special value: simply update the special value to take into
account the second assignment.
closesodoo/odoo#28982
It appears that chrome headless with sandboxing is failing when running
containerized because it tries to use Linux namespaces.
With this commit, the no-sanbox optional arg is used to avoid this
issue.
Closes#26456Closes#28053
From times to times, warning are seen on the runbot during HttpCase
tests with the chrome headless browser.
Those warning are about Odoo trying to join remaining requests threads.
In the dumpstack, the thread seems blocked in the werkzeug
handle_one_request method, when trying to read the HTTP request line.
One explanation could be that Chrome opens a pre-connect socket for
a future use. When the HttpTest cleans the browser, the page stops
loading but (probably) keeps the socket open for a while.
That could explain the problem.
With this commit, a timeout is set on the request handler,
in the hope that it closes the pre-connect socket too.
For unknown [1] reason, phantomjs starts to segfault when running qunit
tests.
Be radical with simply not using phantomjs anymore.
[1] Any guidance on tracking the root cause may help...
Seems like something similar to odoo/odoo#17111 can happen on Python 2.
The same change as #17111 is a bit involved for -stable, but this looks
pretty harmless.
Probably fixes#23781.