[FIX] profiling: avoid crash with thread pools
When using a profiler manually inside the code, and longpolling uses this part of the code, an error will appear on runbot since gevent server cannot be profiled properly. This fix mitigate the issue by disabling the profiler automatically in this case. Part-of: odoo/odoo#78514
This commit is contained in:
+15
-2
@@ -501,8 +501,21 @@ class Profiler:
|
||||
|
||||
def __enter__(self):
|
||||
self.init_thread = threading.current_thread()
|
||||
self.init_frame = get_current_frame(self.init_thread)
|
||||
self.init_stack_trace = _get_stack_trace(self.init_frame)
|
||||
try:
|
||||
self.init_frame = get_current_frame(self.init_thread)
|
||||
self.init_stack_trace = _get_stack_trace(self.init_frame)
|
||||
except KeyError:
|
||||
# when using thread pools (gevent) the thread won't exist in the current_frames
|
||||
# this case is managed by http.py but will still fail when adding a profiler
|
||||
# inside a piece of code that may be called by a longpolling route.
|
||||
# in this case, avoid crashing the caller and disable all collectors
|
||||
self.init_frame = self.init_stack_trace = self.collectors = []
|
||||
self.db = self.params = None
|
||||
message = "Cannot start profiler, thread not found. Is the thread part of a thread pool?"
|
||||
if not self.description:
|
||||
self.description = message
|
||||
_logger.warning(message)
|
||||
|
||||
if self.description is None:
|
||||
frame = self.init_frame
|
||||
code = frame.f_code
|
||||
|
||||
Reference in New Issue