Impacted versions :
- 14.0 and higher
Steps to reproduce :
```
1. generate an odoo.exceptions.RedirectWarning
2. click on the primary button
```
Current behavior :
```
1. the action (argument of the RedirectWarning) is properly executed
2. the WarningDialog is not closed
```
Expected behavior :
```
1. the action should still be properly executed
2. the WarningDialog should be closed
```
Tests :
Added a test to ensure this behavior will not be overwritten in the future.
The test is for the CrashManager service, and evaluates the following sequence :
```
Entry: CrashManager receives a odoo.exceptions.RedirectWarning (code 200) via rpc_error
Asserts:
- The RedirectWarning modal (WarningDialog) should be opened
* Upon clicking on the primary button :
- The modal should be closed
- The action passed as an argument of the odoo.exceptions.RedirectWarning should be executed
```
Origin :
the incorrect behavior was introduced with :
https://github.com/odoo/odoo/commit/b3d9647695065ea582e4a6b0603f3ebf9fde6976
Task ID: 2430100
closesodoo/odoo#64553
X-original-commit: 892598cb0335926ece12789d81673f5b6370a1fd
Signed-off-by: Thibault Delavallee (tde) <tde@openerp.com>